Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Publication year range
1.
Zhongguo Gu Shang ; 37(4): 368-73, 2024 Apr 25.
Article in Chinese | MEDLINE | ID: mdl-38664207

ABSTRACT

OBJECTIVE: To investigate the effect of electroacupuncture therapy on postoperative rehabilitation training of patients with knee fractures. METHODS: Patients with knee fractures from July 2020 to July 2021 were randomly assigned to either the experimental group or a control group according to the double-blind principle. Both groups were given surgical treatment and postoperative conventional rehabilitation training. There were 40 cases in the control group, including 27 males and 13 females;the age ranged from 20 to 66 years old with an average of (36.46±6.29) years old, continuous passive motion (CPM) training was performed after operation. There were 40 patients in the experimental group, including 24 males and 16 females. The age ranged from 21 to 68 years old with an average of (37.62±7.08) years old, on the basis of the control group, electroacupuncture was given. After 4 weeks of intervention, the excellent rate of knee function score, visual analogue scale (VAS) before and after intervention, serum pain mediators, prostaglandin E (PGE), substance P (SP), bradykinin (BK), joint range of motion and quality of life were compared between the two groups. RESULTS: After 4 weeks of intervention, the Rasmussen score for knee function in the experimental group (24.15±1.36) scores was higher than that in the control group (21.25±2.20) scores (P<0.001). The VAS in the experimental group (2.04±0.51) scores was lower than that in the control group (2.78±0.60) after 4 weeks of intervention (P<0.05). Serum PGE (2.25±0.37) mg·L-1, SP (4.43±1.05) ng·ml-1, BK (2.67±0.68) ng·ml-1 in the experimental group were lower than those in the control group (3.91±0.44) mg·L-1, (6.12±1.37) ng·ml-1, (4.55±1.03) ng·ml-1 after 4 weeks of intervention(P<0.05);in the experimental group, the active knee flexion angle of the knee joint was (108.63±9.76)°, the active knee extension angle (-2.46±0.70)°, passive knee flexion angle (116.83±6.57)°, passive knee extension angle (1.44±0.38)° were better than control group (100.24±8.15)°, (-3.51±0.86)°, (111.04±8.22)°, (0.78±0.24)° (P<0.05);the experimental group's psychological score (73.12±5.08), physiological score (72.26±5.89), social function score (72.57±4.23), overall health score (75.12±5.16) were higher than that of the control group (68.49±4.13), (68.13±5.27), (69.04±3.42), and(70.88±3.97) respectvely(P<0.05). CONCLUSION: Electroacupuncture combined with CPM training after knee fracture surgery can significantly improve knee function and range of motion, reduce pain levels, and also improve quality of life and reduce the incidence of adverse events.


Subject(s)
Electroacupuncture , Humans , Male , Electroacupuncture/methods , Female , Middle Aged , Adult , Aged , Range of Motion, Articular , Young Adult , Quality of Life , Postoperative Period , Knee Injuries/surgery , Knee Injuries/rehabilitation , Knee Joint/surgery , Substance P/blood , Double-Blind Method , Fractures, Bone/surgery , Fractures, Bone/therapy , Knee Fractures
2.
Microsc Res Tech ; 78(12): 1146-53, 2015 Dec.
Article in English | MEDLINE | ID: mdl-26531883

ABSTRACT

A fluorescent tracer, poly (acrylic-co-stearyl acrylate-co-3-acryloyl fluorescein) [poly (AA-co-SA-co-Ac-Flu)], used for real-time monitoring the penetration of amphiphilic acrylate copolymer, poly (acrylic-co-stearyl acrylate) [poly (AA-co-SA)], in leather was synthesized by radical polymerization of acrylic, stearyl acrylate and fluorescent monomer, 3-acryloyl fluorescein (Ac-Flu). The structure, molecular weight, introduced fluorescent group content and fluorescent characteristics of the fluorescent tracer and target copolymer, amphiphilic acrylate copolymer, were also characterized. The results show that the tracer presents the similar structural characteristics to the target and enough fluorescence intensity with 1.68 wt % of the fluorescent monomer introduced amount. The vertical section of the leather treated with the target copolymer mixing with 7% of the tracer exhibits evident fluorescence, and the change of fluorescence intensity along with the vertical section with treating time increasing can reflect the penetration depth of the target copolymer. The introduction of the fluorescent group in polymer structure through copolymerization with a limited amount of fluorescent monomer, Ac-Flu, is an effective way to make a tracer to monitor the penetration of the target in leather, which provides a new thought for the penetration research of syntans such as vinyl copolymer materials in leather manufacture.

SELECTION OF CITATIONS
SEARCH DETAIL
...